- Railway
- Tramway
- Cantilever
- Cross-spans
- Crossings
- Disconnectors / Feeds
- Catenary
- De-icing system
- Control units / Electronics
- Soffits / Underpasses
- Tensioning systems
- Tools
- Trolleybus
- Cantilever
- Cross-spans
- Crossings
- Disconnectors / Feeds
- Switches
- Bus Equipment
- Control units / Electronics
- Soffits / Underpasses
- Tools
Disconnect switch Duplex 3.6 kV, 3400 A
added to cart
Display basket
B0898-01
Material and weight
Weight: 28.500 kgSpecification
Operating voltage: 3.6 kV, 3400 AImpulse withstand voltage: mind. 60 kV 1.2/50 us
Nominal withstand voltage to ground: to ground 50 Hz/1min
Nominal withstand voltage to ground: to ground, wet 28 kV eff.
Heating due to constant current: I= 3400 A
Comments
- Power-down ability for emergency cut-down: up to 2000 A/1.5 kV- Lifting: 1 = 120 mm, 2 = 75 mm, 3 = 100 mm